Breaker fault current calculation software

Fault current calculations no transformer known afc this is the most common method and should be used in most projects. If the infinite method is applied when calculating fault current and 4 x fla is added for motor contributions, then the fault current value that is obtained will be very conservative. Must be capable of carrying fault current for a short time while another breaker is clearing. If current exceeds 300% of rated, ampsentry decreases excitation to regulate current at 300% until. The ln fault current is higher than the ll fault current at the secondary terminals of a singlephase centertapped transformer. Ansi fault follows ansi c37 standards for calculating equipment ratings. The devices linked to are cable limiters and normally used to protect the legs of a parallel system to prevent a total outage when one of the parallel cables has a fault. We use the cdegs engineering software from ses technologies. Display the time current curves of 1 to 8 circuitbreakers. Jul 17, 2017 each circuit breaker in your breaker panel is labeled with the maximum amperage current capacity for that circuit. So, if the primary side of your 11kv433v transformer were to fault, the fault current would enter your substations protective earthing system, travel through the earthsoil many kilometers to wherever the source transformer is located, and up that transformers protective earthing system. The programs take into consideration all of the key electrical parameters of power distribution system including power supply, cables, transformers, motors and generators. The prospective shortcircuit current pscc is the maximum current that can flow through a shorted electrical circuit. The city of irving makes no representations, guarantees.

Circuit breaker is a very unique device which is being used widely for the interruption due to occurrence of a fault in the power system. Easy and simple methods for calculating short circuit curr. When you apply these requirements to a circuit breaker, you must calculate the maximum 3phase fault current the breaker will be required to interrupt. Hand calculations are rarely accepted by authorities these days. Fault current interrupting capability and the time it takes for a circuit breaker for switchgear, interrupting rating may also be specified as short circuit mva. Equipment intended to interrupt current at other than fault levels shall have an interrupting rating at nominal circuit voltage sufficient for the current that must be interrupted. This amount of fault current varies based upon the source of power and where the shortcircuit condition is created. Fault level at ht incoming power supply is 360 mva. You cant use current limiting fuses to reduce the available fault current at the meter can.

Ansi shortcircuit short circuit calculation software. You will find sheet with very nice example already fulfilled. In this way, it automatically applies the coefficients and factors of the ansi and iec standards, compares the results with the data published by manufacturers and also emits alarms and warnings when the devices exceed their capacity. Available fault current calculation information form this handout is for informational purposes only and should not be relied on in place of official regulations, policies or city of irving ordinances. Now we can find the fault current using the following formula. Elite software is the worlds premier software developer for hvac, electrical, plumbing, and fire protection design software. Therefore, the circuits supply voltage and its impedance determine the pscc value. How do you calculate the maximum possible available fault. Example to calculate short circuit current for circuit breaker.

It allows to adjust the marginal and critical limits for verification of exceeded equipment. It must be capable of opening the faulty circuit and breaking the fault current. For low voltage systems, the calculations are the same except for two items. It must be capable of being closed on to a fault 3. Factor for calculation of the peak shortcircuit current. The conclusion is that you need to know the fault current value in a system to select and install the correct overcurrent protective devices ocpd. This heavy current can damage the components of the electric system read more. The short circuit current is limited only by the impedance of the system. How to calculate short circuit current of circuit breaker march 8, 2020 february 24, 2012 by electrical4u when there is a short circuit fault in the electrical system, a huge short circuit current flows through the system including the circuit breaker cb contacts, unless the fault.

Nec 2017 requirements for generator set overcurrent. This may differ among circuits, so always check each breaker s capacity individually when calculating the electrical load that will cause that breaker to trip. Determining shortcircuit rating of circuit breakers peguru. The elements in a power distribution system that limit or impede the fault current value include. However, this assumption is not applicable for motor startup calculations where the fault level is used as an input to the motor startup calculation. Electrical calculation tools is a set of 7 computer aided online tools designed to help you. Smartduty, an expert system included with iec shortcircuit, compares each equipment rating with the calculated fault duties, highlighting any problem areas on the oneline and providing a tabular report showing the equipment data, the available fault current, and the critical problem areas. The calculation of circuit breaker interrupting duty depends on how fast it can clear the fault, more specifically, from the time of short circuit initiation up to the time when breaker primary contacts part. Bussmann series fc2 calculatorfault current calculation. Dapper follows a traditional ohms law calculation for fault current.

The available fc will be reduced as shown in the calculations when the fault current value at the primary of the transformer is reduced. Smartduty, an expert system included with shortcircuit, compares each equipment rating with the calculated fault duties, highlighting any problem areas on the oneline and providing a tabular report showing the equipment data, the available fault current, and the critical problem areas. In the interest of continuity of supply, the breaker should not trip in such situations. Comply with ansi, nfpa 70e, nema, and nec standards and regulations. Such breakers are suitable for isolation, but switchdisconnectors are usually also installed so that the equipment can be completely deenergized for service or maintenance. Eaton s online tools, bussmann series fc 2 available fault current calculator, bussmann series oscar 2. This section is dedicated to tools every electrical engineer can use in daily work.

The short circuit module determines fault currents for various balanced and. The gear is being protected by molded case 200a rated circuit breaker mccb. This is the value of the dc component of the shortcircuit current at the time the circuit breaker. Before starting fault current calculation, you will have to choose between step 1a and step 1b which are explained below. Properly engineered and installed selective coordination. Fortunately, short circuit currents are relatively easy to calculate. Transformer short circuit fault current calculator jcalc. Calculation example based upon the ieee 1584 circuit breaker equations consider 575v motor control centre and 20 ka prospective 3phase bolted fault current at its terminals. For instance, if a linetoline fault occurs 50 feet from a transformer, then 100 feet of cable impedance must be included in the calculation.

Figure 1 illustrates a simple singleline diagram that very well could be your basic service entrance for a. Calculate the shortcircuit current at the secondary of the transformer. The calculations on the following pages illustrate 1o fault calculations on a singlephase transformer system. Analyzers, plots and reports allow for quick determination of the worstcase fault current device duty. Generally, circuit breaker ratings are determined for the worstcase fault situation. To calculate cable size and to assist engineers during project expansion. Medium and highvoltage circuit breaker rated cycle. You do not use a formula to calculate the breaker size. As circuit breakers cbs and overcurrent protection devices ocpd are designed for 100% rated current i. This duration is commonly referred to as the circuit breaker contact parting time or cpt. Calculation of system fault levels sp energy networks. Once the fault current has been calculated, labels made giving the available short circuit fault current, should be applied to the equipment. Fault current, or shortcircuit current, that is the question. Up to date with schneider electric low voltage protection devices and circuit breakers.

Circuit breaker interrupting rating calculations pac basics. Use this method when the utility provides the available fault current. Fault current selection for a circuit breaker from a. Electrical ms excel spreadsheets electrical power sector. Simple methods for calculating short circuit current without a. Search all the circuitbreakers that can be selective with a defined circuit breaker. Iec shortcircuit short circuit calculation software. Hello, i have an issue where the fault current at my 480v 3 phase panel is 24,200a and the rating of the panel itself is 22,000 aic, but the main breaker has an interrupting rating of 35,000 aic and the branch circuit breakers have interrupting ratings of 25,000 aic. A breaker needs a fault current rating, because if the current passing through the breaker exceeds that rated value the breaker. Cooper bussmann software programs are available to help you save time in determining a variety of product data and technical information that will help you with design applications and determining electrical values. Fault current calculations are a critical piece of the electrical designengineering puzzle for electrical distribution systems in commercial and industrial installations. For example, a 75kva transformer with a 208y120 secondary and 5% impedance has a capacity of 208 amps on the secondary. Manufacturers specify the fault current interrupting capacity of their breakers for a set of reference conditions including, among other factors, voltage, frequency, decaying dc offset in the fault current, relay operating time, temperature, and altitude.

What is the difference between a comprehensive study. Short circuit calculation short circuit software fault analysis. Or if you have the available fault current, either given to you from utility, or if you are using this program to calculate fault currents at other parts of the system where the aic ampere interrupting capacity is known, input this number and it will automatically override the. The total fault current, must be used for breaker and switchgear sizing and in some specific scenarios for protective relay device coordination. For a branch circuit fault current less than 3600a on the loadside of the 100a circuit breaker, the 400a and 1200a circuit breakers will be coordinated with the 100a circuit breaker. Different methodologies are used to calculate the r x ratio iec.

Short circuit calculation iec 60909 fault analysis. Most of these programs are available to you at no cost through this web site or as a down load to your pc. Are you getting confused between prospective earth fault current and prospective fault current. The nec requires protection to personnel and electrical systems against damage during short circuit conditions.

Be aware that feeder breakers should include the estimated motor. Example to calculate short circuit current for circuit breaker the purpose of this write up is to help the reader estimate the sexample before you hire the pe to do the official calculation. All electrical systems are susceptible to short circuits. Interactive simulation, with a simple mouse click, mimicking realworld breaker switching and shortcircuit results. Input the nameplate transformer impedance as a percentage, not a decimal i. To select circuitbreakers taking into account discrimination. Check the discrimination between two circuitbreakers and display their time current curves. A fault current calculation determines the maximum available current that will be available at a given node, or location, in the system. It includes the action of thermal devices in the short circuit calculation. Scc shortcircuit power tmin minimum dead time for shortcircuit development, often equal to the time delay of a circuit breaker. See note under step 3 of basic pointtopoint calculation procedure. How to calculate short circuit current of circuit breaker. When a short circuit occurs in an electric system, heavy current flows through all the sections of the system which are in the path between the power source and the equipment. Fault current selection for a circuit breaker from a substation layout photo credit.

Sep 11, 2018 in this video, electrical fault level calculation for short circuit faults is shown. Pscc is also known as available fault current or shortcircuit making current. Perform device duty calculations using etaps short circuit analysis software which allows you to determine fault currents and automatically compare these values against manufacturer short circuit current ratings. What do symmetrical, asymmetrical, momentary, interrupting. How to calculate fault current in electrical substation. Calculation of size of transformer, fuse and circuit breaker star. The short circuit current is given by 1to calculate the short circuit current at lv bb 1,the total.

These spreadsheets below will make your job much more easier, alowing you to shorten the time used for endless calculations of cables, voltage drop, various selctions of circuit breakers, capacitors, cable size and so on. If the infinite method is applied when calculating fault current. Note that this assumption will give the worse case fault level on the secondary side of the transformer, which is sufficient for sizing of equipment according to fault rating. Etap short circuit software makes it easy to go from selecting elements, from the comprehensive library of short circuit current ratings, to performing dozens of different types of short circuit analysis. This breaker can interrupt a fault current of 63,000amps or lower at 3cycle mark. Electrical ms excel spreadsheets calculations of cables, voltage. There is not an easy way to limit the current at the meters on that system. Circuit breaker ratings a primer for protection engineers. Panelboard and switchboard short circuit current ratings. Shortcircuitanalytic sca software performs available fault currents calculations in threephase electric power systems you are working with. Fast and easy analysis automatically delivered by the most advanced features in the industry. Fault is cleared by a downstream breaker or generator set is shut down based on.

Short circuit calculation spreadsheet simple tool designed for data estimation and conservative shortcircuit scenarios. The amount of fault current that will be generated at your transformer and the amount of current that will enter the protective earthing system requires very careful calculations. It will also help you in deciding circuit breaker rating. The user defines the prefault fault voltages ansi and the c factor iec. Ieee 1584 circuit breaker equations calculation example. If the fault current is greater than 3600a, then the 400a feeder circuit breaker may unnecessarily open and. Faster than the heavy full features electrical network calculation software. Replacements that result in a higher possible fault current, than that of the existing equipment, shall be addressed to this department, prior to reconnection of existing service equipment. Etap short circuit software program allows for short circuit calculations based. Knowing available fault current levels is vital for compliance with sccr requirements in nec and osha. To preset protection trip unit and to display the result on the time current curve. Calculations in full compliance with iec requirements, ensuring the most accurate and safe equipment duty comparisons. Easypower ansi shortcircuit software delivers intelligent, easytouse tools to. John sokolik and it represents an easy way to calculate fault current by entering few values in indicated fields.

A mobile app and webbased application to make shortcircuit current calculations and help you determine if your equipment installation is compliant with the. Short circuit current calculations cooper industries. Even if there is a utility transformer, most utilities will give you the fault current on the secondary side and you should use this method. Symmetrical and asymmetrical shortcircuit currents. Short circuit current calculation at various point of electrical circuits isc updated. The peak let through with an infinite source worst case scenario would have 208 0. Perform device duty evaluation and calculate unbalanced lg, ll, and llg fault analysis.

Nec publishes tables to use to look up wire size and what breaker to use with that wire. The comprehensive fault follows a traditional ohms law calculation for fault current. Bussmanns fc2 calculator mobile and webbased application is a free tool that provides an easy means for calculating fault current levels and generating nec 110. Calculate fault current at each stage of following electrical system sld having details of. Lets work through another sample calculation where the electric utility fault power level is known click here to see fig. Easily calculate available fault current anytime, anywhere. Short circuit analytic sca software and mobile apps perform available short circuit fault current calculations in threephase electric power systems you are working with. Fc 2 mobile app quickly delivers fault current calculations in the palm of your hand. Overstressed device alarms are displayed on the oneline diagram and included in short circuit analyzer and study reports. Calculate short circuit current of any transformer in just 3. Threephase shortcircuit current isc calculation at any. Electrical system topology are conditionsevenly significant. How to calculate circuit breaker trip settings hunker.

In this video, electrical fault level calculation for short circuit faults is shown. You are a panel builder, electrical calculation tools can help you. Perform device duty calculations using etaps short circuit analysis software which. Sep 28, 2016 watch this video to understand 3 simple steps to calculate short circuit current of any transformer. Figure 1 illustrates a simple singleline diagram that very well could be your basic service entrance for a commercial or industrial installation. Prospective fault current recorded on eic is the greater of prospective earth fault current and prospective short circuit current, so, you have to know or calculate. Once the available fault currents are identified, the system can be designed to provide an acceptable level of. As discussed previously, fault current and shortcircuit current are interchangeable. Makes pointtopoint fault current calculations easy. Verify equipment duty ratings instantly on the oneline. Short circuit complies with iec standards iec 60909. Transformers are often connected to equipment that is rated for certain aic, average interrupting current, or available fault current resolution. After seeing this video, concept of fault level calculation for given single line diagram will be cleared.

Arc flash calculation software and short circuit analysis. For low voltage systems 600v and below, the calculations are the same except for two items. When an arc flash study is being done, the fault current calculation should still be for the highest bolted threephase short circuit current. Receptacle outlets and kitchen appliances do not have fault current ratings, because they don. Circuit breaker ratings breaking capacity making capacity. Short circuit calculation spreadsheet laobing kaisuo. Download32 is source for fault current calculation shareware, freeware download fault current calculator, popcalc pro calculator, design master electrical, powernet, electrc 2008, etc. Lets first consider base kva and kv for ht and lt side. Sometimes a fault on the system is of very temporary nature and persists for 1 or 2 seconds after which the fault is automatically cleared. Circuit breaker sizing calculation for medium and highvoltage circuit breakers basically involves two symmetrical current calculations, one for the first cycle duty and another for the interrupting duty. It is the period for which the circuit breaker is able to carry fault current while remaining closed. Once the fault currents have been calculated, you can then select overcurrent.